Archive: Institute of Measurement Technology


Hint

The Institute of Measurement Technology was dissolved on 30.03.2015 and transitioned into the Institute of Electrical Power and Energy Technology.

Publications

in the field of Environmental Measurement Technology

1999

Matz G., Schröder W., Liebram A.:
A Compact, Non-Scanníng Magnet-MS for Highly Time Resolved Analyses of Gas Mixtures
Pittcon (Orlando), Proc. Paper621, (1999).

Francke W., Schröder W.:
Bicyclic Acetals in Systems of Chemical Communications
Curr. Organic Chemistry, 3, 407-443, (1999).

Matz G., Gohl M., Schröder W.:
Fast Online Measurement of Hydrocarbons in the Exhaust Gas of Combustion Engines by Mass Spectrometry
ASMS Conference on Mass Spectrometry and Allied Topics, P2236-7, (1999).

Matz G., Harig R., Beil A., Daum R.:
Ferndetektion luftgetragender Schadstoffe mit passiver FTIR-Spektrometrie
Düsseldorf: VDI Berichte 1443: "Neuere Entwicklungen bei der Messung und Beurteilung der Luftqualität", 697-706, 1999.

Matz G., Schröder W., Hunte T.:
Gas Detector Array (GDA) for On-Site Detection of Hazardous Compounds
Proc. Of the 7th Int. Conference On-Site Analysis, 0-003, (1999).

Schröder W., Kübler J., Matz G.:
Measurement Strategies for Fast On-Site Separation of Waste Wood treated with Wood Preservatives
AT-ONSITE '99 (San Antonio), (1999).

Matz G., Schröder W., Kübler J.:
On-site Separation of Waste Wood by the detection of Preservatives with Fast IMS-, GC/MS- and XRFS-Analyses
Proc. Sardinia '99, 7th Int. Waste Management and Landfill Symp., "Waste Management and Treatment of municipal and industrial Waste", CISA, Environmental Sanitary Engeneering Centre, Cagliari (Italy), 5, 259-264, (1999).

Matz G., Schröder W., Gohl M., Walte A.:
Online Measurement of Oil-Compounds in the Exhaust Gas of Combustion Engines by Mass Spectrometry
Pittcon (Orlando), Proc. 2078P, (1999).

Schröder W.:
Schnelle Detektion von Holzschadstoffen mit mobilen Geräten
InCom '99 (Düsseldorf), (1999).

1998

Gereit F., Hauptmann P., Matz G., Mellert V., Reuter R.:
An ROV-based sensor system for maritime pollution control
Oceanology International '98 (Brighton).

Matz G., Kibelka G.:
AUTOMATED SAMPLING DEVICE FOR THE CONTROL OF MARINE POLLUTION
Proc. of the Pittcon '98, New Orleans, 1864P.

Matz G.:
Determination of VOCs in Fire and Chemical Accidents by Mobile GC/MS
in "Current Protocols in Field Analytical Chemistry", Unit 1B2, Ed. V. Lopez-Avila John Wiley & Sons Inc. 1998 [ISBN 0-471-17609].

Matz G., Kibelka G., Dahl J., Lennemann F.:
Experimental study on solvent-less sample preparation methods: SBT-Membrane extraction with sorbent interface, thermal membrane desorption application and purge-and-trap
J. Chromat. A, 830, 365-376, 1998.

Schröder W., Matz G., Kübler J.:
Fast detection of Preservatives on Waste Wood: Detection with GC/MS, GC/ECD and Ion Mobility Spectrometry
Field Analytical Chemistry and Technology, 2(5), 287-297, (1998).

Matz G., Hunte T., Döhren S., :
Gas-Detector-Array with Ion-Mobility-Spectrometer for Emergency Response
Proc. of the Pittcon '98, New Orleans, 1974P.

Matz G., Hunte T.:
Gefahrenstoff-Detektoren-Array (GDA) zur Detektion der Gefahrstoffe gemäß ETW-Liste
Tagungsberichte der 7. Internationalen Fachtagung 'Gefährliche Stoffe '98', Salzburg.

Matz G., Loogk M., Lennemann F.:
On-line gas chromatography - mass spectrometry for process monitoring using solvent-free sample preparation
J. Chromat. A, 819, 51-60, 1998.

Matz G., Loogk M., Lennemann F.:
ON-LINE GC/MS FOR PROCESS MONITORING USING SOLVENT-FREE SAMPLE PREPARATION
HTC5 '98 (Brügge).

Schröder W., Matz G., Kübler J.:
Preservatives on Waste Wood: Fast Detection with GC/MS, GC/ECD and Ion Mobility Spectrometry
Field Analytical Chemistry and Technology, 2 (5), 287-297, 1998.

Beil A., Daum R., Matz G., Harig R., :
Remote sensing of atmospheric pollution by passive FTIR spectrometry
EUROPTO '98 (Barcelona).

Beil A., Daum R., Matz G., Harig R.:
Remote sensing of atmospheric pollution by passive FTIR spectrometry
Spectroscopic Atmospheric Environmental Monitoring Techniques, Klaus Schäfer, Herausgeber, Proceedings of SPIE Vol. 3493, 32-43, 1998.

Schröder W., Schillings A., Matz G.:
Self-Made Y-Splits for Hyphenated Capillary Gas Chromatography
J. High Resol. Chromatogr. 21, 125-127, (1998).

Matz G., Hunte T., Döhren S., :
Simple Calibration Gas Generator for easy testing of gas sensors and sensor arrays
Proc. of the Pittcon '98, New Orleans, 2085P.

Matz G.:
Untersuchung der Praxisanforderung an die Analytik bei der Bekämpfung großer Chemieunfälle
Zivilschutzforschung Neue Folge Band 30, 190S., 1998, ISSN 0343-5164.

1997

Münchmeyer W., Walte A., Matz G., Hunte T.:
A novel electronic nose equipped with an enrichment device
Proc. of the Pittcon'97, Atlanta, 612P.

Schröder W., Kibelka G., Matz G.:
Anreicherungskartuschen zur Thermodesorptions-Injektion großer Extraktäquivalente
InCom '97 (Düsseldorf), (1997).

Polomski A., Märkl H., Lennemann F., Matz G.:
Application of a tube membrane probe for on-line monitoring of dissolved gases in fermentation suspensions by membrane introduction mass spectometry (MIMS)
Proc. of the Pittcon'97, Atlanta, 620P.

Matz G., Lennemann F., Märkl H., Polomski A.:
AUTOMATIC PROCESS GAS MONITORING OF BIOREACTORS WITH A MASS SPECTROMETER
Pittcon '97 ,Atlanta, 099P.

Matz G., Jensen A.:
AUTOMATIC TENAX ENRICHMENT UNIT FOR ON LINE AIR MONITORING
Proc. of the Pittcon'97, Atlanta, 516P.

Schröder W., Schillings A., Matz G.:
Einfaches Kalibrierverfahren in der Analytik leicht-flüchtiger organischer Stoffe mit Tenax Anreicherung
InCom '97, Düsseldorf, 121, (1997).

Münchmeyer W., Walte A., Matz G., Lehne J.:
Fast analysis of complex mixtures with membrane inlet mass spectrometry and neural networks
Proc. of the Pittcon'97, Atlanta, 356P.

Matz G., Harder A., Schillings A., Schröder W., Rechenbach P.:
Fast Analysis of Hazardous Organics in Fire and Chemical Accidents by Mobile GC/MS
Proceedings of the "Fifth International Symposium on Field Analytical Methdos for Harzardous wastes and Toxic Chemicals", Las Vegas, USA, 290-296, (1997).

Matz G., Münchmeyer W., Walte A.:
Fast automated analysis of polychlorinated organic compounds in emissions
Proc. of the Pittcon'97, Atlanta, 471P.

Matz G., Schröder W.:
Fast Detection of Wood Preservatives on Waste Wood with GC/MS, GC/ECD and Ion Mobility Spectrometry
Proceedings of the "Fifth International Symposium on Field Analytical Methdos for Harzardous wastes and Toxic Chemicals", Las Vegas, USA, 793-808, (1997).

Matz G., Schröder W.:
Fast On Site GC/MS Analysis of Hazardous Compound Emissions from Fires and Chemical Accidents
Field Analytical Chemistry and Technology, 1(4), 181-194, (1997).

Matz G., Schröder W., Kübler J.:
Field Method for the Detection of Total Petroleum Hydrocarbon in Water and Soil Samples
Proceedings of the "Fifth International Symposium on Field Analytical Methdos for Hazardous Wastes and Toxic Chemicals", Las Vegas, USA, 283-289, (1997 ).

Matz G., Hunte T.:
Gas-Sensoren-Array mit integrierter Anreicherungseinheit
Tagungsband Sensor 97, Nürnberg, 3, 199-204.

Lennemann F., Pahl M., Lunze J., Matz G.:
Massenspektrometrisches Prozeßgas-Monitoring zur modellgestützten Regelung eines Biogas-Turmreaktors
technisches messen, 64, 263-267, 1997.

Matz G., Schröder W.:
Mobile GC/MS Analysis in the Field for the Determination of Toxic Compounds
Proc. Field Screening Europe, Eds.: Gottlieb J., Hötzl H., Huck K., Niessner R. Kluwer Academic Publishers, Dordrecht/Boston/London, ISBN 0-7923-4782-X, (1997).

Schröder W., Matz G.:
Mobile GC/MS-Analytik zur Schnellerkundung leichtflüchtiger Bodenschadstoffe
WLB Wasser Luft und Boden, 9/97, 66-69, (1997).

Steiner U., Sokolow S., Jones L., Matz G., Walte A., Münchmeyer W.:
On-line emission monitoring of semivolatile and chlorinated organic compounds using the rounded hyperbolic quadrupol (RHQ) mass spectrometer
Proc. of the Pittcon'97, Atlanta, 339P.

Matz G., Harder A., Walte A., Münchmeyer W.:
Peak-hopping: A new technique to increase analysis speed in short column GC/MS
Proc. of the Pittcon'97, Atlanta, 389P.

Matz G., Schillings A., Harder A., Schröder W.:
PORTABLE SAMPLING TOOLS FOR ON-SITE ANALYSIS WITH A MOBILE GC-MS SYSTEM
Pittcon (Atlanta), Proc. 474P, (1997).

Matz G., Schillings A., Harder A., Schröder W.:
Sample Preparation for a Mobile GC-MS-System
Proceedings of "the 44th ASMS Conference on Mass Spectrometry and Allied Topics, may 12-16, Portland, Oregon, USA, (1997).

Matz G., Harder A., Schillings A., Rechenbach P.:
Schnellanalyse von organischen Schadstoffen mit mobilem GC/MS-System
Notfall Medizin, 9/97, 412-419.

Matz G., Hunte T.:
Sensor Array with auto-calibration property for the detection of hazardous compounds
Kongreßband, Proc. of the Pittcon'97, Atlanta, 539P.

Matz G., Harder A., Walte A., Münchmeyer W.:
Short Column GC/MS with Increased Analysis Speed by Peak-Hopping
Proceedings of the "Fifth International Symposium on Field Analytical Methdos for Harzardous wastes and Toxic Chemicals", Las Vegas, USA, 705-709, 1997.

Schröder W., Kübler J., Matz G.:
Sum Parameter Evaluation of Toxic Compounds in Water and Soil Samples with Mobile GC/MS
Proc. Field Screening Europe, Ed.: Gottlieb J., Hötzl H., Huck K., Niessner R. Kluwer Academic Publishers, Dordrecht/Boston/London, ISBN 0-7923-4782-X, (1997).

Schröder W., Matz G.:
Wood Preservatives on Waste Wood: Fast Detection with GC/MS, GC/ECD and Ion mobility Spectrometry (IMS)
Proc. Field Screening Europe, Ed.: Gottlieb J., Hötzl H., Huck K., Niessner R. Kluwer Academic Publishers, Dordrecht/Boston/London, ISBN 0-7923-4782-X, (1997).

1996

Matz G., Harder A., Schillings A., Rechenbach P.:
A Mobile GC-MS-System for Fast Analysis of Fires and Chemical Accidents
Special Workshop on Field-Portable Chromatography & Spectroscopy. Snowbird, Utah, USA, P17-31 1996.

Matz G., Schröder W.:
A new fast method for field screening of polychlorinated biphenyls in air
J. Chromat, A, 750, 151-153, (1996).

Matz G., Harder A., Schillings A.:
Application of a Mobile GC-MS-System in Case of Fire and Chemical Accidents
Proceedings of the Pittcon'96, "The Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy", Chicago IL (USA), March 3-8, 630 1996.

Matz G., Münchmeyer W., Walte A.:
Automated Analysis of PAH in Emissions with Thermal Desorption and GC/MS
Proceedings of the Pittcon'96, "The Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy", Chicago IL (USA), March 3-8, 807 1996.

Matz G., Kibelka G.:
Development of an On-Site System for the Detection of Gases and Organic Compounds in Water
Proceedings of "the 44th ASMS Conference on Mass Spectrometry and Allied Topics, may 12-16, Portland, Oregon, USA 1996.

Matz G., Schröder W.:
Fast GC/MS Field Screening for Excavation and Bioremediation of Contaminated Soil
Field Analytical Chemistry and Technolgy, 1, 77-85, (1996).

Matz G., Hunte T., Albrecht T.:
Gas Sensor System for Chemical Accidents and Fires
Proceedings of the Pittcon'96, "The Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy", Chicago IL (USA), March 3-8, 359P 1996.

Matz G., Münchmeyer W., Kibelka G., Walte A.:
Membrane Introduction Mass Spectrometer for Monitoring of Aromatic Compounds in Exhaust Gases
Proceedings of the 44th ASMS Conference on Mass Spectrometry and Allied Topics, may 12-16, Portland, Oregon, USA, 1996.

Matz G., Lennemann F.:
On-line monitoring of biotechnological processes by gas chromatographic-mass spectrometric analysis of fermentation suspensions
J. Chromat., 750, 141-149, 1996.

Matz G., Lennemann F., Märkl H.:
Process Monitoring of Biotechnical Fermentation by GC/MS
Proceedings of the Pittcon'96, "The Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy", Chicago IL (USA), March 3-8, 166P.

Matz G., Schillings A., Harder A., Schröder W.:
Sample Preparation for a Mobile GC-MS-System
Proceedings of "the 44th ASMS Conference on Mass Spectrometry and Allied Topics, may 12-16, Portland, Oregon, USA.

Matz G., Kibelka G.:
Sample Preparation for Semivolatile Organic Compounds
Proceedings of the Pittcon'96, "The Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy", Chicago IL (USA), March 3-8, 986.

Matz G.:
Schnelle GC-MS-Analyse bei Chemieunfällen und Bränden
41. Jahrestagung der Schutzkommission beim Bundesminister des Inneren, Würzburg, 28-30 Mai 1992 Halberstädter Druckhaus GmbH [ISSN 0343-5164], 105-111, 1996.

Matz G.:
Sensorik und GC-MS-Schnellanalytik bei Chemieunfällen und Bränden
42. Jahrestagung der Schutzkommission beim Bundesminister des Inneren, Bad Dürkheim, 20-22. Mai 1993 Halberstädter Druckhaus GmbH [ISSN 0343-5164], 79-89, 1996.

Matz G., Ollesch T., Schröder W.:
Silicoat Filter Thermal Desorption GC-MS for Field Screening of PCBs in Air

Special Workshop on Field-Portable Chromatography & Spectroscopy. Snowbird, Utah, USA P21-P24, (1996).

Matz G., Schillings A., Harder A., Schröder W.:
Tenax Air Sampling Calibration Procedure for Field GC-MS Analysis
Special Workshop on Field-Portable Chromatography & Spectroscopy. Snowbird, Utah, USA, P13-P16, (1996).

Matz G., Schillings A., Harder A.:
Tenax Air Sampling Calibration Procedure for Field GC/MS Analysis
Proceedings of the Pittcon'96, "The Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy", Chicago IL (USA), March 3-8, 632.

Matz G., Kibelka G., Schröder W.:
Wide Range Extract Concentra­tion with Silicoat-Tube for Thermal Desorption GS-MS
Proceedings of the Special Workshop on Field-Portable Chromatography & Spectroscopy. Snowbird, Utah, USA, P17-P20, (1996).

1995

Schröder W., Matz G.:
Boden-GC/MS-Screening im Gelände
TerraTech, 4/1995, 32-36, (1995).

Schröder W., Matz G.:
Feld-Analytik mit GC/MS
WLB Wasser, Luft und Boden, 1-2/1995, 47-50, (1995).

Matz G., Albrecht T., Hunte T.:
Gas-Sensor-Array for Chemical Accidents and Fires
Tagungsband Sensor 95, Nürnberg, 369-374.

Matz G., Harder A., Schillings A., Rechenbach P.:
Mobiles Massenspektrometer im Feuerwehreinsatz
Brandschutz Deutsche Feuerwehr-Zeitung, 1/1995, 41-48.

Matz G., Kübler J., Schröder W.:
Multisampling, Fast Field GC-MS-Analysis and Statistics for Site Investigation and Remediation of Inhomogeneous Soil Contaminants
Contaminated Soil '95, eds. van den Brink, W.J., Arendt F., Kluwer Academic Publishers, Netherlands, (1995).

Matz G., Schröder W.:
New Strategies for Quality Assurance in Fast Soil Analysis in the Field
Proceedings of Contaminated Soil '95, eds. van den Brink, W.J., Arendt F., Kluwer Academic Publishers, Netherlands, (1995).

Walte A., Matz G., Münchmeyer W.:
On-line Abgasanalyse von Aromaten mit mobilem GC-MS
WLB Wasser, Luft und Boden, 3/1995, 54- 57.

Meyer-Jens T., Matz G., Märkl H.:
On-line measurement of dissolved and gaseous hydrogen sulphide in anaerobic biogas reactors
Appl. Microbiol. Biotechnol., 3, 341-345, 1995.

Münchmeyer W., Walte A., Matz G.:
On-line Measurement of Polycyclic Aromatic Hydrocarbons by fast GC/MS
PAC '95 (Ispra).

1994

Matz G.:
Sensorik und GC-MS-Schnellanalytik bei Chemieunfällen und Bränden
Notfallvorsorge und Zivile Verteidigung, 2/1994, 33-39.

1993

Engels E., Engels W., Lübke G., Schröder W., Francke W.:
Age-related patterns of volatile cephalic constituents in queen of the neotropical stingless bee Scaptotrigona postica Latr. (Hymenoptera, Apidae)
Apidologie, 24, 539-648, (1993).

Matz G., Schröder W.:
Fast GC-MS-Analysis of Contaminated Soil: Routine Field Screening in Hamburg
Int. Symposium "Field Screening Methods for Hazardous Wastes and Toxic Chemicals", 2, 963-969, Las Vegas (USA), 1993.

Matz G., Schröder W., Flachowsky, J.:
On-site Investigation of Contaminated Soil by GC-MS and EDXRF-Techniques
Proceedings of the 4th KFK/TNO Conference on Contaminated Soil, Berlin, 3-7. Mai, 657-664, (1993).

Matz G., Kesners P.:
Spray & Trap Method for Water Analysis by Thermal Desorption Gas Chro­matography-Mass Spectrometry in Field Appli­cations
Anal. Chem, 65, 2366-2371, 1993.

Matz G., Harder A., Rechenbach P.:
Spürtrupp unter Vollschutzanzug zur Probenahme vor! Meßtrupp zum Einsatz fertig
Brandschutz Deutsche Feuerwehr-Zeitung, 3/1993, 207-214.

Matz G., Schröder W., Flachowsky J.:
Vor-Ort-Untersuchung verunreinigter Böden durch GC/MS- und EDXRF-Verfahren
F. Arendt, G.J. Annokkèc, R. Bosmann, W.J. van den Brink, "Contaminated Soil '93", 657-664, (1993).

1992

Matz G., Schröder W.:
Fast GC-MS-Analysis of Contaminated Soil: Routine Field Screening in Hamburg
Proceedings of the International Symposium in Central and Eastern Europe, October 12-16, Budapest (Hungary), (1992).

1991

Matz G., Schröder W.:
Schnelle Vor-Ort-Analytik mit einem mobilen Massenspektrometer
Neue Verfahren und Methoden zur Sanierung von Altlasten am Beispiel der Deponie Georgswerder, Hrsg.: Freie und Hansestadt Hamburg, Umweltbehörde/Fachamt für Altlastensanierung, (1991).

1990

Matz G., Schröder W.:
Boden-Schnell-Analytik - Die Erkundung von Altlasten im Feld mit GC/MS-System
LP-Spezial, Chromatographie Spektroskopie, Sonderpublikation der "LaborPraxis" Vogelverlag und Druck KG, Würzburg, 78-80, (1990).

Matz G., Schröder W., Kesners P.:
Schnelle Vor-Ort Bodenanalytik: Ein mobiles GC/MS-System im Vergleich mit Laborverfahren
"Altlastensanierung '90", Band I, S. 869, F. Arend, M. Hinsenveld, W.J. van den Brink, 3. KfK/TNO-Kongress Kluwer Academic Publishers, Dordrecht/Boston/London, (1990).

Engels W., Engels E., Lübke G., Schröder W., Francke W.:
Volatile Cephalic Secretions of Drones, Queens and Workers in Relation to Reproduction in the Stingless Bee, Scaptotrigona Postica (Hymenoptera: Apidae: Trígonini)
Entomol. Gener., 15 (2), 91-101, (1990).