High-Pressure Test Center

Key parameters

  • max. working pressure: 550 bar / 7980 psi
  • experimental volume: 38 liter / 10 gal (DL1), 99 liter /26.2 gal (DL2)
  • zusätzliche Medienspeicher: 40 l, 1 l, 3x 250 ml
  • temperature range: 2 to 50 °C
  • fluid, gaseous and solid test media
  • isobaric/decompression-free media exchange
  • mechanical, electrical, optical and hydraulical access points
  • measurement equipment (standard, others possible): pressure, temperature, mass/volume flow (liquid and gaseous), density, HD video
  • experiments performed: deep-sea simulation, hydrodynamic investigations of natural gas and crude oil, clathrate hydrare synthesis and analysis, structural and functional testing of tools and components under external/internal pressur