Research Interests

  • (arbitrary waveform) Magnetic Particle Imaging
  • inductive sensors, filters and resonant transformers
  • circuit design, impedance matching
  • applications in Magnetic Particle Imaging

Curriculum Vitae

Fabian Mohn studied Electrical Engineering at the Hamburg University of Technology (TUHH) and he joined the group of Tobias Knopp for Biomedical Imaging at the University Medical Center Hamburg-Eppendorf (UKE) and the Hamburg University of Technology in 2020 as a PhD student. Working at Philips Research Laboratories Hamburg, he received his master's degree in 2018 on the Analysis and Optimization of the Signal-to-Noise Ratio for Receive Arrays in Magnetic Resonance Imaging.

Journal Publications

[191084]
Title: Resonant Inductive Coupling Network for Human-Sized Magnetic Particle Imaging.
Written by: F. Mohn, F. Förger, F. Thieben, M. Möddel, I. Schmale, T. Knopp and M. Graeser
in: <em>Review of Scientific Instruments</em>. (2024).
Volume: <strong>95</strong>. Number: (4),
on pages: 044701
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1063/5.0192784
URL:
ARXIVID:
PMID:

Note: article, openaccess, brainimager

Abstract: In magnetic particle imaging, a field-free region is maneuvered throughout the field of view using a time-varying magnetic field known as the drive-field. Human-sized systems operate the drive-field in the kHz range and generate it by utilizing strong currents that can rise to the kA range within a coil called the drive field generator. Matching and tuning between a power amplifier, a band-pass filter, and the drive-field generator is required. Here, for reasons of safety in future human scanners, a symmetrical topology and a transformer called an inductive coupling network are used. Our primary objectives are to achieve floating potentials to ensure patient safety while attaining high linearity and high gain for the resonant transformer. We present a novel systematic approach to the design of a loss-optimized resonant toroid with a D-shaped cross section, employing segmentation to adjust the inductance-to-resistance ratio while maintaining a constant quality factor. Simultaneously, we derive a specific matching condition for a symmetric transmit--receive circuit for magnetic particle imaging. The chosen setup filters the fundamental frequency and allows simultaneous signal transmission and reception. In addition, the decoupling of multiple drive field channels is discussed, and the primary side of the transformer is evaluated for maximum coupling and minimum stray field. Two prototypes were constructed, measured, decoupled, and compared to the derived theory and method-of-moment based simulations.

Conference Proceedings

[191084]
Title: Resonant Inductive Coupling Network for Human-Sized Magnetic Particle Imaging.
Written by: F. Mohn, F. Förger, F. Thieben, M. Möddel, I. Schmale, T. Knopp and M. Graeser
in: <em>Review of Scientific Instruments</em>. (2024).
Volume: <strong>95</strong>. Number: (4),
on pages: 044701
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1063/5.0192784
URL:
ARXIVID:
PMID:

[BibTex]

Note: article, openaccess, brainimager

Abstract: In magnetic particle imaging, a field-free region is maneuvered throughout the field of view using a time-varying magnetic field known as the drive-field. Human-sized systems operate the drive-field in the kHz range and generate it by utilizing strong currents that can rise to the kA range within a coil called the drive field generator. Matching and tuning between a power amplifier, a band-pass filter, and the drive-field generator is required. Here, for reasons of safety in future human scanners, a symmetrical topology and a transformer called an inductive coupling network are used. Our primary objectives are to achieve floating potentials to ensure patient safety while attaining high linearity and high gain for the resonant transformer. We present a novel systematic approach to the design of a loss-optimized resonant toroid with a D-shaped cross section, employing segmentation to adjust the inductance-to-resistance ratio while maintaining a constant quality factor. Simultaneously, we derive a specific matching condition for a symmetric transmit--receive circuit for magnetic particle imaging. The chosen setup filters the fundamental frequency and allows simultaneous signal transmission and reception. In addition, the decoupling of multiple drive field channels is discussed, and the primary side of the transformer is evaluated for maximum coupling and minimum stray field. Two prototypes were constructed, measured, decoupled, and compared to the derived theory and method-of-moment based simulations.