@article{Bohnert2012,
author = {J. Bohnert, M. Graeser, B. Gleich and O. Dössel},
title = {Experimental thresholds of magnetically induced currents via a figure-of-eight coil up to 25 {kHz}.},
journal = {Biomedizinische Technik. Biomedical Engineering.},
year = {2012},
volume = {57.},
number = {(3),},
pages = {185--191},
note = {article},
pmid = {22691426},
doi = {10.1515/bmt-2012-0007},
keywords = {Differential Threshold, Dose-Response Relationship, Radiation, Electric Stimulation, Female, Humans, Magnetic Fields, Male, Muscle Contraction, Muscle, Skeletal, Radiation Dosage, Young Adult,Graeser},
abstract = {Magnetic particle imaging, uses magnetic fields of frequencies in the kilo-hertz range. Little research has been carried out upon effects on excitable tissue caused by time-varying magnetic fields in that frequency range. To learn about magnetic stimulation thresholds, a system that is capable of generating a very focused magnetic field strong enough to induce a muscular reaction was built. Stimulation thresholds at 7.38, 12.04, 16.5, and 25.27 {kHz} have been recorded in 31 trial participants. It has been proved that magnetic stimulation is possible up to even 25 {kHz}, and respective thresholds have been determined. This article presents the trial setup, procedure, and evaluation of field quantities.}
}