Dr.-Ing. Konrad Scheffler

Universitätsklinikum Hamburg-Eppendorf (UKE)
Sektion für Biomedizinische Bildgebung
Lottestraße 55
2ter Stock, Raum 213
22529 Hamburg
- Postanschrift -

Technische Universität Hamburg (TUHH)
Institut für Biomedizinische Bildgebung
Gebäude E, Raum 4.044
Am Schwarzenberg-Campus 3
21073 Hamburg

Tel.: 040 / 7410 25813
E-Mail: konrad.scheffler(at)tuhh.de
E-Mail: ko.scheffler(at)uke.de

Research Interests

  • Magnetic Particle Imaging
  • Image Reconstruction
  • Image Processing

Curriculum Vitae

Konrad Scheffler studied Technomathematics between 2015 and 2021 in Hamburg and graduated with a master's degree thesis on "Enhancing matrix compression using convoluted tensor products of Chebyshev polynomials". He joined the group of Tobias Knopp for Biomedical Imaging at the University Medical Center Hamburg-Eppendorf (UKE) and the Hamburg University of Technology in 2021 as a PhD student and finished his PhD in 2025 on the topic "On Algorithmical Methods Facilitating Clinical Translation of Magnetic Particle Imaging".

Journal Publications

[192352]
Title: Deep learning for restoring MPI system matrices using simulated training data.
Written by: A. Tsanda, S. Reiss, K. Scheffler, M. Boberg, and T. Knopp
in: <em>Physics in Medicine & Biology</em>. (2026).
Volume: <strong>71</strong>. Number: (9),
on pages:
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1088/1361-6560/ae6016
URL:
ARXIVID:
PMID:

Note: article, openaccess, ml

Abstract: Objective. Magnetic particle imaging reconstructs tracer distributions using a system matrix (SM) obtained through time-consuming, noise-prone calibration measurements. Methods for addressing imperfections in measured system matrices increasingly rely on deep neural networks, yet curated training data remain scarce. This study evaluates whether physics-based simulated system matrices can be used to train deep learning (DL) models for different SM restoration tasks, i.e. denoising, accelerated calibration, upsampling, and inpainting, that generalize to measured data. Approach. A large dataset of system matrices was generated using an equilibrium magnetization model extended with uniaxial anisotropy. The dataset spans particle, scanner, and calibration parameters for 2D and 3D trajectories, and includes background noise injected from empty-frame measurements. For each restoration task, DL models were compared with classical non-learning baseline methods. Quantitative performance was evaluated on simulated data using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). For measured data, performance was assessed qualitatively by visual comparison of system matrices and the resulting reconstructions. Main results. The models trained solely on simulated system matrices generalized to measured data across all tasks: for denoising, DnCNN/RDN/SwinIR outperformed discrete cosine transform and soft thresholding baseline by >10 dB PSNR and up to +0.1 SSIM on simulations and led to perceptually better reconstructions of real data; for 2D upsampling, SMRnet exceeded bicubic by ∼ 20 dB PSNR and ∼ 0.08 SSIM at ×2–×4 but these gains did not transfer qualitatively to real measurements. For 3D accelerated calibration, SMRnet matched tricubic in noiseless cases and was more robust under noise, and for 3D inpainting, biharmonic inpainting was superior when noise-free but degraded with noise, while a PConvUNet maintained quality and yielded less blurry reconstructions. Significance. The demonstrated transferability of DL models trained on simulations to real measurements mitigates the data-scarcity problem, which intensifies with model scale. This enables the development of new methods beyond current measurement capabilities and supports pre-training of large models on simulated data.

Conference Publications

[192352]
Title: Deep learning for restoring MPI system matrices using simulated training data.
Written by: A. Tsanda, S. Reiss, K. Scheffler, M. Boberg, and T. Knopp
in: <em>Physics in Medicine & Biology</em>. (2026).
Volume: <strong>71</strong>. Number: (9),
on pages:
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1088/1361-6560/ae6016
URL:
ARXIVID:
PMID:

Note: article, openaccess, ml

Abstract: Objective. Magnetic particle imaging reconstructs tracer distributions using a system matrix (SM) obtained through time-consuming, noise-prone calibration measurements. Methods for addressing imperfections in measured system matrices increasingly rely on deep neural networks, yet curated training data remain scarce. This study evaluates whether physics-based simulated system matrices can be used to train deep learning (DL) models for different SM restoration tasks, i.e. denoising, accelerated calibration, upsampling, and inpainting, that generalize to measured data. Approach. A large dataset of system matrices was generated using an equilibrium magnetization model extended with uniaxial anisotropy. The dataset spans particle, scanner, and calibration parameters for 2D and 3D trajectories, and includes background noise injected from empty-frame measurements. For each restoration task, DL models were compared with classical non-learning baseline methods. Quantitative performance was evaluated on simulated data using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). For measured data, performance was assessed qualitatively by visual comparison of system matrices and the resulting reconstructions. Main results. The models trained solely on simulated system matrices generalized to measured data across all tasks: for denoising, DnCNN/RDN/SwinIR outperformed discrete cosine transform and soft thresholding baseline by >10 dB PSNR and up to +0.1 SSIM on simulations and led to perceptually better reconstructions of real data; for 2D upsampling, SMRnet exceeded bicubic by ∼ 20 dB PSNR and ∼ 0.08 SSIM at ×2–×4 but these gains did not transfer qualitatively to real measurements. For 3D accelerated calibration, SMRnet matched tricubic in noiseless cases and was more robust under noise, and for 3D inpainting, biharmonic inpainting was superior when noise-free but degraded with noise, while a PConvUNet maintained quality and yielded less blurry reconstructions. Significance. The demonstrated transferability of DL models trained on simulations to real measurements mitigates the data-scarcity problem, which intensifies with model scale. This enables the development of new methods beyond current measurement capabilities and supports pre-training of large models on simulated data.