Florian Thieben, M.Sc.

Universitätsklinikum Hamburg-Eppendorf (UKE)
Sektion für Biomedizinische Bildgebung
Lottestraße 55
2ter Stock, Raum 212
22529 Hamburg

Technische Universität Hamburg (TUHH)
Institut für Biomedizinische Bildgebung
Gebäude E, Raum 4.044
Am Schwarzenberg-Campus 3
21073 Hamburg

Tel.: 040 / 7410 25812
E-Mail: f.thieben(at)uke.de
E-Mail: florian.thieben(at)tuhh.de

Research Interests

  • Magnetic Particle Imaging
  • Low Noise Electronics
  • Inductive Sensors

Curriculum Vitae

Florian Thieben is a PhD student in the group of Tobias Knopp for experimental Biomedical Imaging at the University Medical Center Hamburg-Eppendorf and the Hamburg University of Technology. In 2017 he graduated with a master's degree thesis on Entwicklung eines kompakten Magnet Partikel Spektrometers mit gradiometrischer Empfangskette".

Journal Publications

[145074]
Title: Gradient power reducing using pulsed selection-field sequences
Written by: F. Thieben, M. Boberg, P. Szwargulski, M. Graeser, T. Knopp
in: International Journal on Magnetic Particle Imaging 2020
Volume: 6 Number: 2
on pages: 1-3
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.18416/IJMPI.2020.2009054
URL: https://journal.iwmpi.org/index.php/iwmpi/article/view/268
ARXIVID:
PMID:

[doi] [www] [BibTex]

Note: inproceedings

Abstract: Large selection-field power is required to generate a sufficient gradient strength in Magnetic Particle Imaging (MPI). Without cooling, the subsequent heat generation can limit the maximum experiment time. For commercially available MPI scanners a lot of effort was put into active cooling requiring space and infrastructure to dissipate heat. In this abstract, a promising power handling for the selection-field generation is presented. Using a pulsed instead of a continuous selection-field the gradient strength can be increased and no active cooling is required.

Conference Publications

[145074]
Title: Gradient power reducing using pulsed selection-field sequences
Written by: F. Thieben, M. Boberg, P. Szwargulski, M. Graeser, T. Knopp
in: International Journal on Magnetic Particle Imaging 2020
Volume: 6 Number: 2
on pages: 1-3
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.18416/IJMPI.2020.2009054
URL: https://journal.iwmpi.org/index.php/iwmpi/article/view/268
ARXIVID:
PMID:

[doi] [www] [BibTex]

Note: inproceedings

Abstract: Large selection-field power is required to generate a sufficient gradient strength in Magnetic Particle Imaging (MPI). Without cooling, the subsequent heat generation can limit the maximum experiment time. For commercially available MPI scanners a lot of effort was put into active cooling requiring space and infrastructure to dissipate heat. In this abstract, a promising power handling for the selection-field generation is presented. Using a pulsed instead of a continuous selection-field the gradient strength can be increased and no active cooling is required.